What is the R-value of 3 1/2 inch fiberglass insulation?

For example, a wall with 3 ½” fiberglass batting (R-value of 10.8 - 11.9) may have an overall R-value of nearly 14 because of siding, sheathing and drywall.
Takedown request   |   View complete answer on greatdayimprovements.com


What R-value is 3.5 insulation?

The R-value for fiberglass batts ranges from 3.1–3.4 per inch of thickness. For loose-fill fiberglass insulation in an attic, the R-value is 2.2–4.3 per inch and for the wall is 3.7—4.3 per inch. Batts fiberglass insulation is excellent for walls and can be used for attics.
Takedown request   |   View complete answer on attainablehome.com


How many inches of fiberglass insulation is R30?

Typical R-30 fiberglass insulation is 10-inches-thick. Prior to buying fiberglass insulation, it is important to measure the joint spacing you are working with. Note that the actual space between the framing members will be less than 16 or 24 inches, but the foam batts can easily be stuffed between these lengths.
Takedown request   |   View complete answer on homesteady.com


Is R3 insulation good?

It is great for sealing those hard-to-see air leaks (like those around recessed lighting and attic hatches) and for high moisture areas like the crawlspace or basement. We often use spray foam to seal air leaks before installing other types of insulation like cellulose or fiberglass. Spray foam has an R-value of R3.
Takedown request   |   View complete answer on aplusenergyservices.com


Does fiberglass insulation lose R-value when compressed?

When you compress fiber glass batt insulation, the R-value per inch goes up, but the overall R-value goes down because you have less inches or thickness of insulation.
Takedown request   |   View complete answer on energyvanguard.com


Insulation R-VALUE - What is R-Value?



What is the R-value of 4 inch fiberglass insulation?

Batts. Fiberglass batts and rolls are ideal for placement between framing during construction in floors, walls, attics, and ceilings. They're denser than blown-in insulation, offering an R-value of up to 4.3 per inch.
Takedown request   |   View complete answer on eponline.com


Which is better R19 or R30 insulation?

The bigger the R value, the better the insulation is at slowing down the heat transfer. So R19 is better insulation than R13, and R30 is better than R19. The larger the R value, the better the insulation value.
Takedown request   |   View complete answer on patch.com


What is the R-value of loose fill fiberglass?

Loose fill fiberglass has an R-value of R-2.2 to 2.7 per inch3. Achieving the desired R-value depends on both the depth of the insulation and its density. Depending on your climate, energy codes require varying R-values for ceiling insulation.
Takedown request   |   View complete answer on energy.wsu.edu


What is the best R-value for 2x4 walls?

Insulation for 2x4 Walls

In most wall applications, you will use R-13 or R-15 kraft-faced fiberglass insulation rolls for these two-by-four stud walls. While rated differently, these two types of insulation are close enough in thickness that they can both fit into modern two-by-four wall systems.
Takedown request   |   View complete answer on thespruce.com


What insulation has the highest R-value?

Vacuum insulated panels have the highest R-value, approximately R-45 (in U.S. units) per inch; aerogel has the next highest R-value (about R-10 to R-30 per inch), followed by polyurethane (PUR) and phenolic foam insulations with R-7 per inch.
Takedown request   |   View complete answer on en.wikipedia.org


What is a good R-value for exterior walls?

Typical recommendations for exterior walls are R-13 to R-23, while R-30, R-38 and R-49 are common for ceilings and attic spaces. See the Department of Energy's (DOE) ranges for recommended levels of insulation below.
Takedown request   |   View complete answer on jm.com


Is r40 insulation good?

The recommended R value from professionals for attic insulation in Ontario is R 50 and R 60. So, in general a higher R value means a better insulated attic.
Takedown request   |   View complete answer on ecostarinsulation.ca


What is the R-value of 6 inches of fiberglass insulation?

Fiberglass blankets or rolls provide an R-value of up to 3.2 per inch, so a 6-inch fiberglass batt may achieve an R-value of 19.2, and some high-performance products are rated at R-21.
Takedown request   |   View complete answer on homeguides.sfgate.com


Can you put blown in insulation over batt insulation?

If the vapor retarder is correctly positioned, that is under the insulation directly against the ceiling, you can blow insulation over the batts. In fact, the batt and blow approach is a recommended and common technique for overcoming the endemic problems of batt installation.
Takedown request   |   View complete answer on cellulose.org


What is the thickness of R-38 insulation?

The R-38 high-performance batts are 10˝ to 10-1/4˝ thick as opposed to stan- dard R-38 fiber glass insulation batts of 12˝.
Takedown request   |   View complete answer on insulationinstitute.org


How high is R38 insulation?

Insulation levels are specified by R-Value. R-Value is a measure of insulation's ability to resist heat flow. The higher the R-Value, the better the thermal performance of the insulation. The recommended level for most attics is to insulate to R-38 or about 10 to 14 inches, depending on insulation type.
Takedown request   |   View complete answer on energystar.gov


Can you use too much insulation?

It is possible to over-insulate your house so much that it can't breathe. The whole point of home insulation is to tightly seal your home's interior. But if it becomes too tightly sealed with too many layers of insulation, moisture can get trapped inside those layers. That's when mold starts to grow.
Takedown request   |   View complete answer on reenergizeco.com


Does squashing insulation stop it working?

Can cause damp – as standard boarding is placed onto the joists of your roof, this will inevitably squash your insulation, which stops it from working and will cause condensation to build up as it doesn't have room to breathe.
Takedown request   |   View complete answer on instaloft.co.uk