How many toilets can you put on a 4 inch line?

3 tank-type toilets, one urinal, 4 sinks. a drinking fountain. 2 Floor drains.
Takedown request   |   View complete answer on reddit.com


Can you run two toilets on the same line?

Most houses have more than one toilet, and if they are on the same side of the house, their waste lines can usually tie into the same stack. If they are on opposite sides, however, each may need its own stack.
Takedown request   |   View complete answer on homeguides.sfgate.com


How many toilets can you have on a 3-inch vertical drain?

There is one answer. The International Plumbing Code requires 5 Drainage Fixture Units in a bathroom group. It's good for 20 DFU's or 4 bathroom groups.
Takedown request   |   View complete answer on homex.com


Should toilet drain be 3 or 4-inch?

Related Articles. Waste drain pipes for toilets in modern plumbing systems are either 3 inches or 4 inches in diameter. The wider the pipe, the more waste it can move and the less likely it will be to clog. A 4-inch pipe can carry about twice the waste of a 3-inch pipe.
Takedown request   |   View complete answer on homeguides.sfgate.com


Does every toilet need a vent pipe?

“Does a toilet need a vent?” And the answer is yes, your toilet has to have a vent. For more information on the great importance of plumbing vents, read our plumbing vent article here. And the size of this vent pipe depends on your local plumbing code.
Takedown request   |   View complete answer on hammerpedia.com


How Many Bathrooms With Toilets Can You Have In Your House - Plumbing Drain Pipe Size Matters



How far can toilet be from Stack?

2. Tie the waste line from the new toilet directly into the stack if the toilet is within six feet of the stack and the waste line is 3 inches in diameter. If the waste line is 4 inches in diameter, the toilet can be as far as 10 feet from the stack.
Takedown request   |   View complete answer on homeguides.sfgate.com


Can a toilet and a sink share the same drain?

Yes, the sink can tie into the same drain. Be sure to use a trap! Personally, I would make the sink connection to the drain as close as possible to the vertical.
Takedown request   |   View complete answer on diy.stackexchange.com


What size pipe should be used for a toilet?

The standard size for a toilet drain pipe is 3 inches in diameter, but drains up to 4 inches in diameter are sometimes used. Typically, 3-inch pipes carry the water to the toilet, but a 4-inch pipe may be used to move wastewater out of a house to a sewer or septic tank.
Takedown request   |   View complete answer on hunker.com


Can two toilets share one vent?

The waste lines can usually be tied into the same stack if the house has more than one toilet. They may need their own stack if they are on opposite sides. Two vent openings on the roof are needed since the stacks must be vented.
Takedown request   |   View complete answer on homex.com


Can toilets be back to back?

New construction uses a 45° double wye fitting for back-to-back toilet installations. The "Y" connector directs the water downward, eliminating direct flow into the opposite waste line.
Takedown request   |   View complete answer on support.kohler.com


Can a shower share a toilet drain?

In short, it is possible to connect the toilet drainage line and the shower drainage line, as long as they both have separate waste trap arms. However, do note that combining them may also lead to blockages, which can cause smells to come from certain drains.
Takedown request   |   View complete answer on victoriaplum.com


Can I vent a toilet through a sink drain?

In conclusion, you can connect the sink drain to the toilet vent if the sink and the toilet vent are not far from each other. If it is not possible to connect a sink drain to the toilet drain within six feet of the toilet, you can install another vent on the toilet drain near the toilet.
Takedown request   |   View complete answer on nimvo.com


Can a toilet and sink share a vent?

Wet venting is most common in conjunction with toilets and sinks; the drain for the sink is also the vent for the toilet. It can also be used for a variety of other applications but due to the following rules this is the most convenient and common situation to run into.
Takedown request   |   View complete answer on jaytechplumbing.com


How do you calculate sewer pipe capacity?

6.2.1.1 Pipe Capacities

The Continuity equation and the Manning equation for steady-state flow can be used to calculate flow in a sewer pipe: Continuity Equation: Q = V*A Where: Q = peak flow, cubic feet per second (cfs). V = velocity, feet per second (fps). A = cross-sectional area of pipe, square feet (sf).
Takedown request   |   View complete answer on cityoforoville.org


How do you increase flow rate in a pipe?

In a fluid passing through a pipe, a reduction in the diameter of the pipe can compress the flowing fluid. It flows faster, which increases the flow rate. And if the diameter increases, then the flow rate reduces.
Takedown request   |   View complete answer on pipingmart.com


How far can a toilet drain without a vent?

According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.
Takedown request   |   View complete answer on plumbersstock.com


Does a toilet stack have to go straight down?

Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.
Takedown request   |   View complete answer on bhg.com


How long can a toilet pipe be?

Six metres is the maximum run according to Building Regualtions, but as you have realised yourself, a good fall on the branch pipe is essential. 2.5º, or 44mm fall for every metre run, is the usual standard. IIRC it is permissible (but inadvisable) to go as low as 18mm per metre, the maximum is 90mm per metre.
Takedown request   |   View complete answer on mybuilder.com


Can two bathrooms share a vent stack?

Well, you can't! You'd often blow air from one bathroom into the other, and local building inspectors wouldn't approve it. But while you can't have two fans with one vent, you can make one fan and one vent serve two bathrooms.
Takedown request   |   View complete answer on familyhandyman.com
Previous question
What percentage of Ireland is white?
Next question
How many eyes have a mosquito?