How far can a toilet be from the main vent stack?

Toilet Vent Distance
According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.
Takedown request   |   View complete answer on plumbersstock.com


How close does a toilet need to be to a main stack?

1. Install the new toilet within six feet of the main soil stack in your house, if possible. The main stack is a length of 3- or 4-inch pipe that runs vertically from the main bathroom to the sewer. The diameter of the stack above the main bathroom reduces to 2 or 3 inches and extends through the roof.
Takedown request   |   View complete answer on homeguides.sfgate.com


Can a toilet and shower share a vent?

So yes the shower can also be vented by the wet vent along with the toilet. There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent.
Takedown request   |   View complete answer on diy.stackexchange.com


How far can toilet be from vent?

According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.
Takedown request   |   View complete answer on plumbersstock.com


How far can a toilet be from the main drain?

If the toilet is less than six feet from the stack, tie the waste line from the new toilet directly into the stack. The toilet can be as far as 10 feet from the stack if the waste line is 4 inches.
Takedown request   |   View complete answer on homex.com


How Far Should a Plumbing Vent Be From the Fixtures? : Plumbing Repair



Does each toilet need its own vent?

“Does a toilet need a vent?” And the answer is yes, your toilet has to have a vent. For more information on the great importance of plumbing vents, read our plumbing vent article here. And the size of this vent pipe depends on your local plumbing code.
Takedown request   |   View complete answer on hammerpedia.com


Can a vent be upstream from a toilet?

A toilet vent can be upstream. The purpose of the vent pipe is to allow the sewer's gases to escape from the house's roof rather than inside the house. A vent also allows oxygen to enter into the sewer pipes, which allows the waste to break down and prevents clogging.
Takedown request   |   View complete answer on whatblueprint.com


Can 2 toilets share the same vent?

Most houses have more than one toilet, and if they are on the same side of the house, their waste lines can usually tie into the same stack. If they are on opposite sides, however, each may need its own stack. Since the stacks must be vented, this would mean two vent openings on the roof.
Takedown request   |   View complete answer on homeguides.sfgate.com


Can a toilet and sink share a vent?

A general rule is that you can only vent 2 fixtures on a toilet wet vent. The sink drain has a toilet vent through it. The toilet drain should be 3′′, the sink drain is 1.5′′, the shared sink drain/toilet vent area should be 2′′, and the vent going up should be 1.5′′.
Takedown request   |   View complete answer on homex.com


How far can a vent pipe be from the drain?

For pipes that have a diameter of 3 inches the distance is 6 feet and for a 4-inch pipe the most it should be away from the vent is 10 feet. Keep in mind that toilets have their own traps so there is no need to have one on the drain line, but it still must have a vent.
Takedown request   |   View complete answer on scottenglishplumbing.net


Can a bath and toilet share the same drain?

Conclusion. In short, it is possible to connect the toilet drainage line and the shower drainage line, as long as they both have separate waste trap arms. However, do note that combining them may also lead to blockages, which can cause smells to come from certain drains.
Takedown request   |   View complete answer on victoriaplum.com


How many toilets can be on a 4 inch drain?

3 tank-type toilets, one urinal, 4 sinks. a drinking fountain. 2 Floor drains.
Takedown request   |   View complete answer on reddit.com


How many fixtures can be on a 2 inch vent?

The Plumbing Code states that a vent can handle 24 fixture units. A bathroom sink of 1.0 F.U., a bathtub of 2.0 F.U., and a shower of 2.0 F.U.
Takedown request   |   View complete answer on homex.com


Where should plumbing vent be located?

Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.
Takedown request   |   View complete answer on bhg.com


What happens if a toilet is not vented?

Poorly-vented drain lines will not be able to effectively move wastewater and solid waste out of your building. This could lead to problems such as overflowing drains, backed-up toilets, and similar plumbing issues.
Takedown request   |   View complete answer on sobieskiinc.com


Can you put a cheater vent on a toilet?

Don't worry if you do not have a vent pipe in your house, or if it is blocked and you can't fix it. Instead of thinking about massive construction projects, you can use an Air Admittance Valve, well-known as a cheater vent.
Takedown request   |   View complete answer on sunrisespecialty.com


Can two bathrooms share a vent stack?

If you have two bathrooms that are close together and one has an exhaust fan and the other doesn't, you might be wondering if you can tie a new exhaust duct into the existing one. Well, you can't! You'd often blow air from one bathroom into the other, and local building inspectors wouldn't approve it.
Takedown request   |   View complete answer on familyhandyman.com


Can you have one vent pipe in a bathroom?

In new construction, the simplest way to vent a bathroom group is usually to install a single vertical vent pipe behind the bathroom sink. This works as long as all the plumbing fixtures connect to the main drain line in the floor within 6 to 10 lineal feet of the sink drain.
Takedown request   |   View complete answer on homeguides.sfgate.com


Can a vent stack have bends in it?

One should avoid bends and turns in the vents to ensure that there is no possibility of a trap. If it is being placed horizontally, ensure that it is at an angle no more than 45 degrees. Essentially, the vent pipe needs to be dry at all times.
Takedown request   |   View complete answer on pvcworkshop.com


Is 3 inch drain OK for toilet?

Waste drain pipes for toilets in modern plumbing systems are either 3 inches or 4 inches in diameter. The wider the pipe, the more waste it can move and the less likely it will be to clog.
Takedown request   |   View complete answer on homeguides.sfgate.com


How many plumbing vents can be tied together?

You can usually tie up to eight fixtures to a single stack, but local codes differ, so it's a good idea to check.
Takedown request   |   View complete answer on homeguides.sfgate.com