How far can a toilet be from a vent stack?

According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.
Takedown request   |   View complete answer on plumbersstock.com


How far can a toilet vent be from toilet?

That means your fixture drain can have an unlimited distance (909.1). Keep in mind your toilet still needs a vent, but your trap arm can be as long as necessary. Now on the other hand, if your plumbing code is the UPC, they're not as generous… In the UPC, the toilet's trap to vent distance is limited to 6 feet.
Takedown request   |   View complete answer on hammerpedia.com


Can a toilet and shower share a vent?

So yes the shower can also be vented by the wet vent along with the toilet. There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent.
Takedown request   |   View complete answer on diy.stackexchange.com


Can a toilet and sink share a vent?

Wet venting is most common in conjunction with toilets and sinks; the drain for the sink is also the vent for the toilet. It can also be used for a variety of other applications but due to the following rules this is the most convenient and common situation to run into.
Takedown request   |   View complete answer on jaytechplumbing.com


Can you vent a toilet with a 2-inch pipe?

Toilet vent pipes are usually configured by feeding a 2-inch PVC pipe within the wall in back of the toilet down from the ceiling. This pipe connects right into the toilet drain pipe. Then, the tub/shower drain pipe and sink drain pipe are vented with 1.5-inch pipe, and these branch off the toilet pipe.
Takedown request   |   View complete answer on homeguides.sfgate.com


How Far Should a Plumbing Vent Be From the Fixtures? : Plumbing Repair



How far can a vent pipe be from the drain?

For a 1 ½-inc pipe the vent should be 42 inches away at the most while a 2-inch pipe must have a maximum distance of 5 feet. For pipes that have a diameter of 3 inches the distance is 6 feet and for a 4-inch pipe the most it should be away from the vent is 10 feet.
Takedown request   |   View complete answer on scottenglishplumbing.net


How high above the roof should a vent pipe be?

Unless a roof is to be used for any purpose other than weather protection, extensions of vent pipes through a roof should be terminated at least 12 inches above the roof. The vent should be extended at least seven feet above the roof if it is to be used for something other than weather protection.
Takedown request   |   View complete answer on homex.com


Can you use one vent for the whole bathroom?

In new construction, the simplest way to vent a bathroom group is usually to install a single vertical vent pipe behind the bathroom sink. This works as long as all the plumbing fixtures connect to the main drain line in the floor within 6 to 10 lineal feet of the sink drain.
Takedown request   |   View complete answer on homeguides.sfgate.com


Can a bath and toilet share the same drain?

Conclusion. In short, it is possible to connect the toilet drainage line and the shower drainage line, as long as they both have separate waste trap arms. However, do note that combining them may also lead to blockages, which can cause smells to come from certain drains.
Takedown request   |   View complete answer on victoriaplum.com


Can a plumbing vent be upstream or downstream?

So can a toilet vent be upstream? A toilet vent can be upstream. The purpose of the vent pipe is to allow the sewer's gases to escape from the house's roof rather than inside the house. A vent also allows oxygen to enter into the sewer pipes, which allows the waste to break down and prevents clogging.
Takedown request   |   View complete answer on whatblueprint.com


Do all toilets need a soil stack?

As the new w.c. appears to be at the head of a single line the answer is yes. The purpose of a vent stack is to save the trap from being pulled out with the outflow with the resulting problem of drain stench in the toilet.
Takedown request   |   View complete answer on community.screwfix.com


Can shower and sink Share vent?

Keeping this in mind, you will want to know, can a shower and sink share a drain? Yes, the shower and sink can share the same drain. This is done using a vent as long as the two fixtures are close to each other.
Takedown request   |   View complete answer on dropbymyhouse.com


What happens if you don't vent a toilet?

Poorly-vented drain lines will not be able to effectively move wastewater and solid waste out of your building. This could lead to problems such as overflowing drains, backed-up toilets, and similar plumbing issues.
Takedown request   |   View complete answer on sobieskiinc.com


Does a plumbing vent have to be straight?

Plumbing vents need to be straight on the vertical. This is necessary to avoid any vapor locks from occurring. When there is a bend in the vent pipe, moisture accumulates and is trapped.
Takedown request   |   View complete answer on ehow.com


How high does a toilet vent pipe need to be?

The International Plumbing Code requires plumbing vent pipes to be at least 6 in. Section 905.5 deals with vent connections and grades above a roof. Vent pipes must be at least 12 in. It is away from a vertical surface.
Takedown request   |   View complete answer on homex.com


What is the difference between vent stack and stack vent?

A vent stack is a vertical pipe that is only used for venting, and runs upward from the drain piping to the open air outside the home. Vent stacks are primary vents and accept connections from other vents in a plumbing system. A stack vent is used for both drainage and venting.
Takedown request   |   View complete answer on howtolookatahouse.com


What is the minimum number if inches a vent pipe can extend out of the roof?

All open vent pipes that extend through a roof shall be terminated at least 6 inches (152 mm) above the roof and not less than 2 inches (51 mm) above the invert of the emergency overflow, except that where a roof is to be used for any purpose other than weather protection, the vent extensions shall be run at least 7 ...
Takedown request   |   View complete answer on rooferscoffeeshop.com


How far can ap trap be from vent?

trap, the distance from the weir of the trap to the vent pipe opening “shall not” exceed 30 inches.
Takedown request   |   View complete answer on ncwhomeinspections.com


Does a vent stack have to be vertical?

Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.
Takedown request   |   View complete answer on bhg.com


How far can vent be from sink?

Install the vent between the sink P-trap and the point where the waste line leading from the trap drops to the main sewer. If the waste line has a diameter of 1 1/4 inches, the vent can be no farther than 2 1/2 feet from the trap. If the waste line is 1 1/2 inches, this critical distance is 3 1/2 feet.
Takedown request   |   View complete answer on homeguides.sfgate.com


How far away can a vent be from a shower drain?

The connection between the fixture drain and the horizontal drain and vent pipe is the only vertical pipe of a combination drain and vent system. 8 feet is the maximum vertical distance.
Takedown request   |   View complete answer on homex.com


Do I need a vent for every drain?

Without getting too far into building science, a general plumbing rule of thumb is that every drain needs a trap, and every trap needs a vent. All those traps and drains are designed to prevent sewer gas from entering your home.
Takedown request   |   View complete answer on familyhandyman.com


Can you vent a drain horizontally?

To answer your specific question, yes, vent pipes can have horizontal runs, as long as there is no possibility of them becoming plugged with water. In other words, any water that gets into the vent pipe opening must be able to run freely all the way to the sewer, without creating a "trap".
Takedown request   |   View complete answer on diy.stackexchange.com


Do you need a stench pipe with every toilet?

All bathrooms need a vent pipe otherwise there will be a possibility that the traps will be pulled when things like the toilet is flushed or the bath emptied. A Durgo valve can be fitted internally instead of having to extent the soil pipe outside.
Takedown request   |   View complete answer on mybuilder.com
Next question
How old is WRLD?