How far can a drain pipe run horizontally?

If you have 1- 1/4-inch pipe, the horizontal distance of the vent ought to not be more than 30 inches. For a 1- 1/2-inc pipe the vent must be 42 inches away at the most while a 2-inch pipeline must have an optimum distance of 5 feet.
Takedown request   |   View complete answer on southendplumbingllc.com


How long can a horizontal drain be?

Building codes, plumbing codes and not being able to cut through floor joist in the top and bottom 2” of joist, the pipe generally leaves only 4” to run horizontally and drop at a rate of ¼” per foot of horizontal travel. Therefore, drain line can only run 16 feet before dropping into the ceiling.
Takedown request   |   View complete answer on anchorseweranddraincleaning.com


How far can you run a drain pipe?

The ICC organization's plumbing codes state that there should be a vent pipe within five feet of any drain. With your new location 35 feet away from the main stack (which is of course vented), you're too far away from that one, so you'll need to tie into another vent stack.
Takedown request   |   View complete answer on diy.stackexchange.com


Can you run a drain horizontally?

Drain piping can be horizontal (1/4” per foot), vertical, or 450- vent piping shall be free of sags and be graded and connected to drip back by gravity to drain pipe it serves.
Takedown request   |   View complete answer on co.lincoln.wa.us


How far can a plumbing fixture be from the main stack horizontally?

and any such vent terminal shall not be within 10 feet (3048 mm) horizontally of such an opening unless it is at least 2 feet (610 mm) above the top of such opening.
Takedown request   |   View complete answer on inspectapedia.com


The Proper Slope For Drain Pipe-Plumbing Basics



Can you vent a drain horizontally?

To answer your specific question, yes, vent pipes can have horizontal runs, as long as there is no possibility of them becoming plugged with water. In other words, any water that gets into the vent pipe opening must be able to run freely all the way to the sewer, without creating a "trap".
Takedown request   |   View complete answer on diy.stackexchange.com


Does every drain need a vent?

Without getting too far into building science, a general plumbing rule of thumb is that every drain needs a trap, and every trap needs a vent. All those traps and drains are designed to prevent sewer gas from entering your home.
Takedown request   |   View complete answer on familyhandyman.com


Can a drain pipe have a 90 degree elbow?

It's fine to have a larger-radius (sweep) 90-degree bend at the base of a vertical drainage stack where the wastewater starts to travel horizontally. It's also a good idea to have a sweep 90-degree fitting where a drain pipe pops out of a wall for a kitchen, vanity or laundry sink.
Takedown request   |   View complete answer on washingtonpost.com


How far can you run a 2-inch drain pipe?

A 2-inch-diameter pipe sloped at 1/4 inch per foot results in a drop equal to the pipe's internal diameter over a distance of 8 feet: 1/4 inch x 8 = 2 inches (see “Maximum Allowable Trap Arm Length,” above).
Takedown request   |   View complete answer on jlconline.com


Can you use a 90 degree elbow on a toilet drain?

All change-of-direction fittings buried under a slab should never have any 90-degree fittings. If you need to change direction under concrete or other buried piping conditions say in a sewer line, you use two 45-degree fittings. It's a best practice to separate the 45-degree fittings by at least 6 inches, if possible.
Takedown request   |   View complete answer on washingtonpost.com


How far can you run a toilet drain?

Tie the waste line from the new toilet directly into the stack if the toilet is within six feet of the stack and the waste line is 3 inches in diameter. If the waste line is 4 inches in diameter, the toilet can be as far as 10 feet from the stack.
Takedown request   |   View complete answer on homeguides.sfgate.com


Can a drain pipe have too much slope?

The ideal slope of any drain line is ¼ inch per foot of pipe. In other words, for every foot the pipe travels horizontally, it should be dropping ¼ inch vertically. Many drains either have too little slope or too much slope. That's right, it is possible to have too much slope in your drain lines.
Takedown request   |   View complete answer on mrplumberatlanta.com


How far can a drain go without a vent?

If you have 1 ¼-inch pipe, the horizontal distance of the vent should not be more than 30 inches. For a 1 ½-inc pipe the vent should be 42 inches away at the most while a 2-inch pipe must have a maximum distance of 5 feet.
Takedown request   |   View complete answer on scottenglishplumbing.net


How far can drain be from sink?

The most common kitchen counter height is 36 inches, but it can vary from 30 to 45 inches. The standard kitchen sink is 8 inches deep, which means that the normal distance between a kitchen sink drain and the floor is 28 inches. This will vary, depending on the height of the counter and the depth of the sink bowl.
Takedown request   |   View complete answer on homeguides.sfgate.com


Can you put a 90 in a vent pipe?

Tips for Installing Vent Pipes

Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.
Takedown request   |   View complete answer on bhg.com


Can two drains share a vent?

Common vent

This very simple concept allows two traps to be vented by the same vent. The two traps and their fixture drains can be either at the same level or at different levels, provided that they are on the same floor. The following diagrams show some of the various approaches to common venting.
Takedown request   |   View complete answer on iccsafe.org


Can you use a sanitary tee horizontal?

A sanitary tee should be used when connecting a horizontal run, such as a waste arm to a vent stack or vertical riser.
Takedown request   |   View complete answer on ncwhomeinspections.com


Can a washer and toilet share the same drain?

This isn't uncommon. Your washing machine might have been placed in between your toilet and sewer stack. * If your toilet and washing machine drains are connected, they have the same venting system. This can cause your toilet to gurgle when your washer drains.
Takedown request   |   View complete answer on newflowplumbing.com


What slope is required for a toilet to drain?

The plumbing code requires drain pipe to be sloped at a minimum of 1/2 inch per foot and a maximum of three inches per foot or vertical. A slope of less than a quarter-inch per foot will cause a lot of drain clogs and a slope of more than three inches will allow the water to drain.
Takedown request   |   View complete answer on homex.com


What is a street 90 in plumbing?

These wrought (wrot) copper street elbows are used to connect a copper pipe to a copper fitting at a 90-degree angle. Manufactured to ASTM and ANSI standards from commercial grade C12200 alloy used by leading copper pipe fitting manufacturers such Nibco and Mueller.
Takedown request   |   View complete answer on pexuniverse.com


Can a toilet and sink share a vent?

Wet venting is most common in conjunction with toilets and sinks; the drain for the sink is also the vent for the toilet. It can also be used for a variety of other applications but due to the following rules this is the most convenient and common situation to run into.
Takedown request   |   View complete answer on jaytechplumbing.com


Does plumbing vent go before or after trap?

We must always keep the vent connection above the trap weir to prevent siphoning and keep proper pressures on both side of the trap.