Do toilets need a vent pipe?

“Does a toilet need a vent?” And the answer is yes, your toilet has to have a vent. For more information on the great importance of plumbing vents, read our plumbing vent article here. And the size of this vent pipe depends on your local plumbing code.
Takedown request   |   View complete answer on hammerpedia.com


Can a toilet be installed without a vent?

What is a ventless toilet and how does it work? Ventless toilets are just like regular ones, except there is no vent for the toilet to release the water vapor. Instead, they use a siphon action that pulls the water out of the toilet bowl into an underground waste pipe.
Takedown request   |   View complete answer on kitcheninfinity.com


What happens if a toilet is not vented?

Poorly-vented drain lines will not be able to effectively move wastewater and solid waste out of your building. This could lead to problems such as overflowing drains, backed-up toilets, and similar plumbing issues.
Takedown request   |   View complete answer on sobieskiinc.com


How close to the toilet does a vent pipe need to be?

According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.
Takedown request   |   View complete answer on plumbersstock.com


Why does a toilet need a vent pipe?

Vent pipes supply fresh air to each plumbing fixture in the house, which helps the system move water through the drainage pipes each time a toilet is flushed or a sink is drained. Plumbing air vents also prevent sewer gases from entering the home and allow wastewater gas and odor to escape.
Takedown request   |   View complete answer on ahs.com


Does Toilet Need Vent Pipe?



Can a shower and toilet share a vent?

Wet vents are typically used when plumbing a bathroom group. So yes the shower can also be vented by the wet vent along with the toilet. There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent.
Takedown request   |   View complete answer on diy.stackexchange.com


How do you vent a toilet without outside access?

How to Vent Your Bathroom with no Outside Access
  1. Vent beneath the floor. If your bathroom is situated away from your exterior wall, venting through the roof is impossible. ...
  2. Add a ceiling vent. ...
  3. Expand your bathroom ducts. ...
  4. Add a recirculating fan for your half bath. ...
  5. Install commercial ductwork. ...
  6. Add a fan.
Takedown request   |   View complete answer on experthomereport.com


Where does the vent pipe go on a toilet?

Toilet vent pipes are usually configured by feeding a 2-inch PVC pipe within the wall in back of the toilet down from the ceiling. This pipe connects right into the toilet drain pipe. Then, the tub/shower drain pipe and sink drain pipe are vented with 1.5-inch pipe, and these branch off the toilet pipe.
Takedown request   |   View complete answer on homeguides.sfgate.com


Can 2 toilets share the same vent?

Most houses have more than one toilet, and if they are on the same side of the house, their waste lines can usually tie into the same stack. If they are on opposite sides, however, each may need its own stack. Since the stacks must be vented, this would mean two vent openings on the roof.
Takedown request   |   View complete answer on homeguides.sfgate.com


Do plumbing vents have to go through the roof?

It does not have to go through the roof. From the plumbing code (I have the 2003 edition), P3103: It must not be less than 4 feet directly beneath a door, openable window or other air intake of the building or adjacent building.
Takedown request   |   View complete answer on houzz.com


Does a toilet need an extractor fan?

Any new kitchen, bathroom (or shower room), utility room or toilet should be provided with a means of extract ventilation to reduce condensation and remove smells.
Takedown request   |   View complete answer on planningportal.co.uk


Does toilet need air to flush?

Slowly Draining Toilets

This is because ample supply of air is needed for water to drain properly. This is exactly what a vent system does, it makes use of an open pipe going through the roof to let air circulate in the plumbing system.
Takedown request   |   View complete answer on scottenglishplumbing.net


Can a toilet be vented through a wall?

You can pass the vent through a wall instead of through the roof, but it must still rise over the roof.
Takedown request   |   View complete answer on homeguides.sfgate.com


Can you vent a toilet in the attic?

Yes, a plumbing vent can terminate in the attic. But it must have an air admittance valve at the termination to keep noxious sewer gas fumes from rising into the attic.
Takedown request   |   View complete answer on howtolookatahouse.com


Can you vent a toilet from behind?

There are many different ways to vent your fixtures, and you're going to want to cater to the factors present in your bathroom. The most common configuration is to feed 2" PVC down from the ceiling within the wall behind the toilet. The vent pipe connects into the toilet drain pipe.
Takedown request   |   View complete answer on plumbersstock.com


How far can a vent pipe be from the drain?

For pipes that have a diameter of 3 inches the distance is 6 feet and for a 4-inch pipe the most it should be away from the vent is 10 feet. Keep in mind that toilets have their own traps so there is no need to have one on the drain line, but it still must have a vent.
Takedown request   |   View complete answer on scottenglishplumbing.net


Can I vent plumbing out the wall?

In many jurisdictions you have the option of an AAV - Air Admittance Valve, readily installed in a wall box behind the washer. An AAV involves a gravity seal that opens just when needed to let fresh air into the plumbing pipe. Just makes sure what you get is a real AAV, not just a cheap $3 check valve.
Takedown request   |   View complete answer on diy.stackexchange.com


Can a toilet vent run horizontal?

There is no problem with running your vent pipes horizontally as long as you remember that there should be a minimum clearance of 6 inches above the spill line. What is a spill line? This is the level where the water starts to overflow from the rim of the sink, toilet, or tub.
Takedown request   |   View complete answer on southendplumbingllc.com


Can a vent be upstream from a toilet?

A toilet vent can be upstream. The purpose of the vent pipe is to allow the sewer's gases to escape from the house's roof rather than inside the house. A vent also allows oxygen to enter into the sewer pipes, which allows the waste to break down and prevents clogging.
Takedown request   |   View complete answer on whatblueprint.com


Can a toilet and shower share the same drain?

The general answer is that the showers and toilets can use the same drain, but they should not be sharing the same waste trap arm. There are other factors to consider as well, such as whether your drains lead to the main sewer line, or if there are septic tanks that are used in your city or town.
Takedown request   |   View complete answer on victoriaplum.com


How do I vent a bathroom with no windows?

Best Ways to Improve Ventilation in a Bathroom Without a Window
  1. Use an Exhaust Fan. ...
  2. Wipe Any Spills and Drips. ...
  3. Open All the Doors. ...
  4. Place Portable Fans. ...
  5. Use a Dehumidifier. ...
  6. Don't Dry Towels Inside. ...
  7. Use a Moisture Absorber.
Takedown request   |   View complete answer on homeairadvisor.com


Can you vent toilet with sink vent?

Wet venting is most common in conjunction with toilets and sinks; the drain for the sink is also the vent for the toilet. It can also be used for a variety of other applications but due to the following rules this is the most convenient and common situation to run into.
Takedown request   |   View complete answer on jaytechplumbing.com


Does a washing machine drain need a vent?

All plumbing fixtures—including washing machines—must be vented. Improperly vented drains can be sluggish and noisy, and can emit hazardous fumes. Properly vented drains allow the P-trap to do its job: prevent sewer gases from escaping into your home.
Takedown request   |   View complete answer on maplewoodplumbing.com