How far can toilet be from vent?

According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.
Takedown request   |   View complete answer on plumbersstock.com


How far can a toilet be from the main drain?

If the toilet is less than six feet from the stack, tie the waste line from the new toilet directly into the stack. The toilet can be as far as 10 feet from the stack if the waste line is 4 inches.
Takedown request   |   View complete answer on homex.com


Can a toilet and shower share a vent?

So yes the shower can also be vented by the wet vent along with the toilet. There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent.
Takedown request   |   View complete answer on diy.stackexchange.com


How far can a fixture be from a vent?

For a 1 ½-inc pipe the vent should be 42 inches away at the most while a 2-inch pipe must have a maximum distance of 5 feet. For pipes that have a diameter of 3 inches the distance is 6 feet and for a 4-inch pipe the most it should be away from the vent is 10 feet.
Takedown request   |   View complete answer on scottenglishplumbing.net


Can a toilet and sink share a vent?

Wet venting is most common in conjunction with toilets and sinks; the drain for the sink is also the vent for the toilet. It can also be used for a variety of other applications but due to the following rules this is the most convenient and common situation to run into.
Takedown request   |   View complete answer on jaytechplumbing.com


How Far Should a Plumbing Vent Be From the Fixtures? : Plumbing Repair



Does a toilet need a vent stack?

“Does a toilet need a vent?” And the answer is yes, your toilet has to have a vent. For more information on the great importance of plumbing vents, read our plumbing vent article here. And the size of this vent pipe depends on your local plumbing code.
Takedown request   |   View complete answer on hammerpedia.com


What happens if you don't vent a toilet?

Poorly-vented drain lines will not be able to effectively move wastewater and solid waste out of your building. This could lead to problems such as overflowing drains, backed-up toilets, and similar plumbing issues.
Takedown request   |   View complete answer on sobieskiinc.com


Can you vent a toilet with a 2-inch pipe?

Toilet vent pipes are usually configured by feeding a 2-inch PVC pipe within the wall in back of the toilet down from the ceiling. This pipe connects right into the toilet drain pipe. Then, the tub/shower drain pipe and sink drain pipe are vented with 1.5-inch pipe, and these branch off the toilet pipe.
Takedown request   |   View complete answer on homeguides.sfgate.com


How long can a plumbing vent be?

If you have 1- 1/4-inch pipe, the horizontal distance of the vent ought to not be more than 30 inches. For a 1- 1/2-inc pipe the vent must be 42 inches away at the most while a 2-inch pipeline must have an optimum distance of 5 feet.
Takedown request   |   View complete answer on southendplumbingllc.com


Do plumbing vents have to go through the roof?

It does not have to go through the roof. From the plumbing code (I have the 2003 edition), P3103: It must not be less than 4 feet directly beneath a door, openable window or other air intake of the building or adjacent building.
Takedown request   |   View complete answer on houzz.com


Can you use one vent for the whole bathroom?

In new construction, the simplest way to vent a bathroom group is usually to install a single vertical vent pipe behind the bathroom sink. This works as long as all the plumbing fixtures connect to the main drain line in the floor within 6 to 10 lineal feet of the sink drain.
Takedown request   |   View complete answer on homeguides.sfgate.com


Does a plumbing vent have to be straight?

Plumbing vents need to be straight on the vertical. This is necessary to avoid any vapor locks from occurring. When there is a bend in the vent pipe, moisture accumulates and is trapped.
Takedown request   |   View complete answer on ehow.com


Can a shower drain be connected to a toilet drain?

In short, it is possible to connect the toilet drainage line and the shower drainage line, as long as they both have separate waste trap arms. However, do note that combining them may also lead to blockages, which can cause smells to come from certain drains.
Takedown request   |   View complete answer on victoriaplum.com


How far can a toilet be from a vent stack Ontario?

Apparently there is a requirement in the Ontario Building Code that vertical air vents connected to drains not be located more than 5' (or 1500mm or so) from a fixture or drain. I have searched for this requirement in the Code for an hour to no avail.
Takedown request   |   View complete answer on forums.redflagdeals.com


Can a toilet waste pipe be moved?

There is usually a vertical waste water pipe under the toilet that uses gravity to move wastewater away. For the waste water line, an offset toilet flange will allow you to move the toilet a couple of inches in any direction without having to cut a new hole in the floor or reconstruct the waste water pipe.
Takedown request   |   View complete answer on mrrooter.com


How far can vent be from sink?

Install the vent between the sink P-trap and the point where the waste line leading from the trap drops to the main sewer. If the waste line has a diameter of 1 1/4 inches, the vent can be no farther than 2 1/2 feet from the trap. If the waste line is 1 1/2 inches, this critical distance is 3 1/2 feet.
Takedown request   |   View complete answer on homeguides.sfgate.com


How does a cheater vent work?

A cheater vent (or air admittance valve) is a vent that comes off the fixture -- for example, a sink in a new powder room -- and is buried in the wall. (You can usually hear them sucking in air and gurgling behind the wall when the fixture drains.)
Takedown request   |   View complete answer on homes.winnipegfreepress.com


Where should a plumbing vent be located?

Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.
Takedown request   |   View complete answer on bhg.com


How do you vent a bathroom with no outside access?

Installing a ceiling vent is probably the most efficient way to ventilate a bathroom with no outside access. A ceiling vent is a unique machine that allows air to escape from the bathroom. In other words, it's a machine that, like an open window, allows moisture to escape from your bathroom.
Takedown request   |   View complete answer on smartremodelingllc.com


Does the vent go before or after the toilet?

​Connect the Vent Underneath the Toilet:​ If the toilet waste pipe drops vertically to a long-sweep elbow, you can install the vent in the vertical pipe before the fitting. You would do this with a reducing wye with its sweep pointing downward and use elbows to change the direction of the vent pipe as needed.
Takedown request   |   View complete answer on hunker.com


Where is the toilet vent pipe located?

It will be found in a basement or crawlspace coming straight down from your house. In most cases it will be made of either cast iron or, in modern homes, PVC pipe, usually colored black. Most of these pipes will be at least 3 inches in diameter. Have someone flush the toilet and listen for a large draining sound.
Takedown request   |   View complete answer on homeguides.sfgate.com


Do I need a vent for every drain?

Without getting too far into building science, a general plumbing rule of thumb is that every drain needs a trap, and every trap needs a vent. All those traps and drains are designed to prevent sewer gas from entering your home.
Takedown request   |   View complete answer on familyhandyman.com


How far above the roof should a vent pipe be?

Unless a roof is to be used for any purpose other than weather protection, extensions of vent pipes through a roof should be terminated at least 12 inches above the roof. The vent should be extended at least seven feet above the roof if it is to be used for something other than weather protection.
Takedown request   |   View complete answer on homex.com


Does every sink drain need a vent?

Every sink needs a sink vent. A plumbing fixture like a sink can not function properly without a sink vent.
Takedown request   |   View complete answer on diy.stackexchange.com