What is the R-value of 3.5 inches of spray foam?

The R-value of open cell spray foam is about 3.5 per inch, although the R-value can be different depending on the product. Open cell spray foam has a low density and is many times applied in interior walls and areas that are hard to reach in a home.
Takedown request   |   View complete answer on southlandinsulators.com


What is the R-value of 3 inches of closed cell spray foam?

The R-value of closed-cell foam is R-6.5-7 per inch. Contractors often use it to insulate under slabs, ceilings, walls, and roofs. It performs better than other insulation types.
Takedown request   |   View complete answer on tigerfoam.com


What is the R-value per inch of spray foam?

Open-cell spray foam has an R-value of about R-3.7 per inch, while closed-cell spray foam has an R-value that may be as high as R-6.5 per inch.
Takedown request   |   View complete answer on finehomebuilding.com


What is the R-value of spray foam in a 2x4 wall?

Open-cell spray foam has an R-value of about R-3.7 per inch, while closed-cell spray foam has an R-value that may be as high as R-6.5 per inch. If you want to install spray foam in a stud wall, and price is no object, then it would seem to make sense to specify closed-cell spray foam, right? Not necessarily.
Takedown request   |   View complete answer on greenbuildingadvisor.com


How many inches of spray foam insulation do I need?

Now generically speaking, we usually recommend open cell spray foam to be 6- to 10-inches on a roof deck or ceiling and 3-inches in the walls. Closed cell spray foam should be 4- to 5- inches on the ceiling and 2- to 3-inches in the walls.
Takedown request   |   View complete answer on retrofoamofmichigan.com


What is the R-Value of Spray Foam Insulation? | Foam University



What is the R-value of 4 inches of spray foam?

Spray Foam Insulation R-Value

Open cell spray foam insulation is R-3.6 to R-3.9 per inch. This R-Value is normal for open cell spray foam.
Takedown request   |   View complete answer on retrofoamofmichigan.com


How thick should my spray foam be?

“Normally, what we teach is that all foam applications should be installed in 3/4-inch to 3-inch-thick lifts. If foam is applied thick and quick — say, 4 inches thick — you gain yield. You can cover more wall with less foam. But the foam will be less dense.
Takedown request   |   View complete answer on insulationinstitute.org


What is the thinnest insulation with highest R-value?

Aerogel insulation offers the highest R-value of any insulating material at less weight and thickness—ideal for construction, refineries, pipelines, and thin-gap thermal barriers.
Takedown request   |   View complete answer on buyaerogel.com


What is the R-value of 2 inch closed cell spray foam?

This microscopic difference in the two products creates a dramatic difference in performance. Closed cell spray foam has an R-value of R-7 per inch. In comparison, open cell spray foam has an R-value of R-3.8 per inch. Additionally, the materials have decidedly different densities.
Takedown request   |   View complete answer on jm.com


How thick is r30 insulation?

8¼ ” thick, R-30C EcoTouch® Thermal Batt insulation prevents moisture damage and helps assure long roof life by providing 1" of ventilation air space between the insulation and roof deck. Easy Installation R-30C EcoTouch® Thermal Batt insulation is easy to handle and install.
Takedown request   |   View complete answer on www2.owenscorning.com


What insulation has the highest R-value per inch?

Vacuum insulated panels have the highest R-value, approximately R-45 (in U.S. units) per inch; aerogel has the next highest R-value (about R-10 to R-30 per inch), followed by polyurethane (PUR) and phenolic foam insulations with R-7 per inch.
Takedown request   |   View complete answer on en.wikipedia.org


Is spray foam worth the cost?

If you see the benefit of insulating your new construction home correctly from the start for long-term comfort, energy savings month after month, and fewer headaches while you live in the house, then spray foam insulation may very well be worth the extra cost to you.
Takedown request   |   View complete answer on retrofoamofmichigan.com


Does great stuff have an R-value?

Two-part closed cell spray foams have R values ranging from R-5 to R-6.1 per inch. Single-part Great Stuff™ sealants are used to fill smaller areas where air and moisture can flow.
Takedown request   |   View complete answer on awarehousefull.com


What is the highest R-value for spray foam insulation?

Spray Foam

The foam (usually polyurethane) is sprayed to fill cracks and gaps in the attic to form a hermetically sealed barrier. Spray foam provides the highest R-value – while open cell spray foam has about an R-value of 2.2 to 3.5 per inch, closed cell spray foam has about 6-7 per inch.
Takedown request   |   View complete answer on foamtechnw.com


Do you need a vapor barrier with spray foam?

A vapour barrier is not necessary with closed-cell foam but with open-cell spray foam such as Icynene®, it is sometimes required. Any air that migrates though a building envelope will carry water vapour. As Icynene® spray foam creates a seamless air-seal, it controls air leakage and the moisture in the air.
Takedown request   |   View complete answer on massfoamsystems.co.uk


Which is better closed or open cell foam insulation?

Closed cell foam has a higher R-value than open cell foam, usually about 6.0 per inch. But some closed cell foams, like Tiger Foam's E84 Closed Cell formula, have even higher ratings that go up to almost 7 per inch. This higher rating makes closed cell foam better at keeping heat in or out of a structure.
Takedown request   |   View complete answer on tigerfoam.com


What is the best R-value for 2x4 walls?

Insulation for 2x4 Walls

In most wall applications, you will use R-13 or R-15 kraft-faced fiberglass insulation rolls for these two-by-four stud walls. While rated differently, these two types of insulation are close enough in thickness that they can both fit into modern two-by-four wall systems.
Takedown request   |   View complete answer on thespruce.com


What is the R-value of 4 inch fiberglass insulation?

Fiberglass insulation does not have the highest R-value on the market, but it is one of the most cost-conscious options. The R-value for fiberglass batts ranges from 3.1–3.4 per inch of thickness. For loose-fill fiberglass insulation in an attic, the R-value is 2.2–4.3 per inch and for the wall is 3.7—4.3 per inch.
Takedown request   |   View complete answer on attainablehome.com


What is the R-value of 1/2 inch Styrofoam?

STYROFOAM extruded polystyrene insulation is rated at an R-value of 5.0 per inch at 75°F.
Takedown request   |   View complete answer on twperry.com


What is a good R-value for exterior walls?

Typical recommendations for exterior walls are R-13 to R-23, while R-30, R-38 and R-49 are common for ceilings and attic spaces. See the Department of Energy's (DOE) ranges for recommended levels of insulation below.
Takedown request   |   View complete answer on jm.com


What is the R-value of a vacuum?

VIPs have better insulating properties than conventional materials. A one-inch thick vacuum insulated panel can provide an insulating value of R-25 to R-30.
Takedown request   |   View complete answer on e3tnw.org


What is the thinnest r38 insulation?

R-Values. Insulation thickness determines its thermal resistance, or R-value. The thicker the insulation, the greater the R-value. An insulation value of R-38 is at the high end and requires a minimum thickness of 12 inches.
Takedown request   |   View complete answer on homeguides.sfgate.com


Is spray foam better than regular insulation?

When compared with other insulation products, spray foam insulation offers the highest R-Value per installed inch. Because spray foam will completely seal and insulate the “building envelope”,, allowing for the ultimate in thermal protection (and R-Value). Spray foam can be closed-cell or open-cell.
Takedown request   |   View complete answer on gni.ca
Next question
How far will a 6 iron go?